MODEL “190RBW”
Medium Duty Roller Bed Wire Mesh Belt Conveyor
Applications / Features
- Drying Operations
- Wet or Oily Products
- Hot or Cold Parts from Ovens or Freezers
- One Direction Operation
Online Resources:
STANDARD SPECIFICATIONS
Belt – 12″, 18″, 24″ and 36″ wide, 1/2″x1″ flat wire belt.
Bed – 1.9″ diameter rollers mounted on 6″ centers in 6-1/2″ deep x 12 gauge powder painted formed channel, bolted together with splice plates and supports.
Drive Sprockets – 6″ pitch diameter cast iron sprockets machined for 1-3/16″ diameter shaft.
Tail Pulley – 4″ diameter with 4″ pitch diameter cast iron sprockets on each end of pulley, 1-3/16″ diameter shaft.
Snub Roller – Adjustable 2″ diameter roller located directly behind drive sprockets and tail sprockets.
Return Idlers – 1.9″ diameter, adjustable, on 10’0″ centers.
Take-Up – 6″ long screws located at tail pulley to tighten belt.
Bearings – Sealed and pre-lubricated with heavy duty housing.
Floor Supports – Adjustable 31″ to 45″ from floor to top of belt. One support supplied at each end of conveyor and at each bed joint.
Speed Reducer – C-Face mounted heavy duty worm gear reducer.
Motor – 1/2 HP 230/460-3-60 TE motor.
Belt Speed – 60 FPM constant.
Capacity – Maximum load per linear foot of conveyor – 75 pounds. Not to exceed Load Capacity Chart.
(For Optional Equipment, Weight Specifications, and Engineering Line Drawings, please see catalog pages, above).
(Optional colors available at extra cost)
OPTIONAL EQUIPMENT
Belt – 1/2″ x 1/2″ flat wire, galvanized, stainless steel. Others.
Guard Rails – Adjustable channel, continuous channel, or solid steel guard rails available.
Floor Supports – Lower or higher supports available.
Ceiling Hangers – 1⁄2″ diameter threaded rods 8 feet long with locking nuts and mounting hardware. Other lengths are available.
Side Mounted Drive – End drive mounted to side of conveyor. Specify side. Minimum elevation – 10″.
Overhead Drive – End drive mounted above conveyor. Specify clearance required.
Motor – Single phase, energy efficient, explosion proof, etc. Other HP available.
Belt Speed – Constant and variable belt speeds available.
Electrical Controls – Magnetic starters and push button stations; manual motor starters with overload protection, others.